Proven, not just promised: the testing behind the Certus™ mechanically fixed brick slip façade system
Brick slip systems are increasingly specified on higher-risk buildings (HRBs), and on those projects a performance claim is only worth the evidence behind it.
Increased use on HRBs
For Certus™, that evidence covers fire performance, weather performance and thorough golden thread records that follow every panel from design, through to factory production, and to site. Certus™ has been used on major HRB projects, including two landmark London residential developments: Hallsville Quarter in Canning Town and Leven Road in East London.
ACS have tested the Certus™ mechanically fixed brick slip façade system in large scale tests with varying cavity build-ups.
This includes testing with other products typically specified and used in the cavity in conjunction with or interfacing with Certus™, including fire barriers.
Fire performance
In recent years, test evidence for façade systems has been scrutinised far more closely. Testing requirements to support and validate performance of façade systems has extended beyond simply demonstrating compliance with Approved Document B, including the use of non-combustible materials and testing to BS 8414-2. For the specifier, the question is how the system behaves in a fire, not only how it is classified.
Certus™ is classified A1 non-combustible to BS EN 13501. The system is made from stainless steel, which has a much higher melting point than aluminium. That limits both lateral and vertical spread of heat through the material and retention of integrity
The interface with the cavity barrier is where many systems are most exposed. ACS have tested both open and closed state barriers in a range of fire tests. Ventilated façades require an open ventilated cavity in the outer wall cavity, Certus™ has been tested with open state intumescent barriers. The cavity stays ventilated in normal use.
When exposed to a fire load, the intumescent expands and seals against the flat Certus™ interface. This testing has been carried out with cavity barriers from Siderise, Tenmat and Rockwool, and ACS continue to test alongside other manufacturers. For a specifier, that means:
- Results are already available for common open and closed state barrier combinations
- System specific fire performance can be demonstrated and evidenced to assist specifiers
- The testing programme is an ongoing process to enhance the catalogue of tested buildups and interfaces
- Testing can be carried out on a project-by-project basis, using your own specification
Weather performance
In normal service a rainscreen façade is exposed to cycles of water, wind, impact and temperature change for the life of the building. Certus™ is tested to CWCT standards:
| Test | Reference |
| Water penetration, static | CWCT Section 6 |
| Water penetration, dynamic (aero engine) | CWCT Section 7 |
| Water penetration, hose | CWCT Section 9 |
| Wind resistance, serviceability | CWCT Section 11 |
| Wind resistance, safety | CWCT Section 12 |
| Impact, retention of performance and safety to persons | CWCT TN 76 |
Durability is tested separately. Hygrothermal testing subjects a wall frame, clamped to the face of a 2.4 m high by 3.0 m long test aperture, to repeated heating and cooling. It follows clause 5.4.6 of EAD 090062-00-0404. Freeze-thaw cycling runs from -20°C to +70°C.
Thermal performance and condensation risk are currently assessed by calculation and 3D modelling, project by project. Certus™ panels form a ventilated rainscreen, so air moves freely through the cavity, the façade panels have little effect on through-wall U-value. The bracketry is usually the critical component in these calculations because it bridges the cavity insulation. Certus™ can be designed with aluminium or stainless-steel brackets, which are less thermally conductive than when compared to aluminium materials commonly used.
Testing proves performance. Traceability proves that the system on site is the same one that was tested and specified.
Every Certus™ panel is photographed and carries a unique QR code, so it can be tracked from the factory floor to its final position on the building. The record goes well beyond baseline requirements, capturing the materials used and the operative who manufactured each panel, and it stays with the panel all the way onto site.
The result is a complete, panel-specific record of both production and design information. Certus™ designs are compatible with BIM Level 2 and 3, so specifiers can work within a common data environment under BIM protocols.
This golden thread of information supports Gateway 2 and beyond. On a higher-risk building, the Building Safety Regulator must be satisfied that the façade will meet the Building Regulations before construction can begin. With test evidence, product data and design information held in one traceable record, compliance is far easier to demonstrate.
Testing and traceability are only part of the picture when specifying a brick slip façade system. Specifiers also have to weigh cost, buildability and the wider demands of the Building Safety Act, and these factors often decide whether a façade makes it through to construction.
ACS is running an online CPD, Introducing Certus™ Mechanically Fixed Brick Slip Façade System, on Wednesday 2nd December, 12.30pm to 1.30pm. Testing and golden thread are covered as are thermal performance, value engineering and the Building Safety Act. Register for this educational session, hosted by ACS Engineering Director Matt Freeman here.
Article originally published on 15th October 2026