C Type Windpost
C-Type Windposts are generally specified for masonry panels that experience lower wind loads. Installed entirely within the cavity, it leaves the blockwork coursing and stretcher bonding undisturbed, eliminating the need for cutting blockwork on site.
As with all ACS windposts, C Type posts are selected from a design table based on the length, section and loading requirements of your project, often eliminating the need for additional steel or reinforced concrete columns and reducing the time and cost involved in this method of construction.
Technical Data Sheets
Certifications
General Guidance
Strength And Stability For Lower Wind Loadings
Simple To Install
Want to learn more about our Windposts?
Specifying windposts for a masonry panel? Share your panel height, wind loading and cavity width with our Technical Engineering Team and we’ll confirm the right section, fixings and layout details your project requires.
Get in touch
Key Specification Details
- Designed for lower wind loadings, installed entirely within the cavity
- Leaves blockwork coursing and stretcher bonding undisturbed, with no cutting of blockwork, and uses WPT1 clip-on ties to both the external and internal leaf to transfer loads back to the structure
- Standard sections from 55 x 60 x 4mm up to 115 x 60 x 6mm, with factored loads up to 16.5kN depending on post height
- Designed as simply supported beams to Eurocodes 3 and 6, with maximum deflection of height/360 and maximum stress of 191N/mm² (Grade 304), and ties designed to BS EN 845
- Parapet post versions available, designed as fixed base cantilevers up to 2.0m in height
- Supplied with a rigid base connection and a slotted top cleat for movement and tolerance
- Austenitic stainless steel, or carbon steel where specified, CCPI-assessed, with standard or bespoke designs from our technical team
More Than a Manufacturer. A Compliance Partner.
Every ACS customer benefits from ACS Assured – our framework built on three pillars: Compliance Through Expertise, Assurance Through Transparency, and Performance & Innovation. From Gateway 2 documentation to full product traceability and sustainable manufacturing credentials, it’s built into everything we supply.
Compliance Through Expertise
Assurance Through Transparency
Performance & Innovation
CPD Series
Tested, Certified, Trusted
C Type Windposts are designed to Eurocodes 3 & 6, with ties designed to BS EN 845, and have achieved a Code for Construction Product Information (CCPI) mark for clear, accurate product information.
Download NBS/BIM
Access the NBS specification and BIM resources for this product to support your project planning, specification and design.
Request the CAD file
Need the CAD file for this product? Submit a request using our form and our team will be in touch.
Technical Data Sheet
The ACS Windposts Technical Data Sheet covers product highlights, product summary, installation guidance, and full design tables for L, C and Spine section windposts and their parapet post variants.